The NRCB is the first and only combination boiler on the market that can simultaneously provide domestic and space heating for residential applications. These simultaneous capabilities are easy to control and especially beneficial for applications that do not store or deliver heat energy efficiently. A user can, for example, take a shower without worrying about experiencing a corresponding drop in room temperature.
Another industry first is the NRCB’s use of 316L stainless steel primary and secondary heat exchangers, which have higher corrosion resistance than traditional heat exchangers for increased durability and lifespan. A third flat plate heat exchanger for domestic water heating is also made of stainless steel.
It also far exceeds the toughest emissions standards. The unit’s fully modulating burner has a nitrogen-oxide emissions level of only 14 parts per million (ppm), far below the South Coast Air Quality Management District requirement of 20 ppm.
-Fuel saving performance from this unit boasts 95% thermal efficiency
-Austenite stainless steel heat exchangers allow for greater durability
-Simultaneous operation of domestic hot water and heating
-Ultra low emissions by premix burner
-Domestic Mode: 90°F to 140°F - Heating Mode: 100°F to 180°F
-Unit has a minimum of 18,000 BTU/H, maximum of 199,900 BTU/H for standard input, 18,000 BTUh to 120,000 BTUh for heating mode input
-10-year limited warranty on the heat exchanger, 5 year on parts, and 1 year labor warranty
-Flow rates of 0.4 GPM up to 11.1 GPM
Overview
Residential or Commercial |
Residential Combination Boiler |
|
Installation Location |
Indoor Only |
|
Exhaust Type |
2-pipe Direct Vent (SV convertible) |
|
Max Flow Rate |
11.1 GPM |
|
Flow Rate @ 50°F Rise |
8.0 GPM |
|
Flow Rate @ 80°F Rise |
|
|
Temperature Range |
90°F - 140°F DHW & (100°F - 180°F Heating) |
|
Production Status |
Active |
|
Condensing |
Yes |
|
Minimum Activation Flow Rate |
0.4 |
|
Water Quality |
|
|
Freeze Protection |
Yes |
|
Freeze Protection Rating - Indoor Temp |
-30°F |
|
Freeze Protection Rating - Outdoor Temp |
N/A |
|
Recirculation Compatible ? |
Yes |
|
New Generation Model Number |
N/A |
|
Previous Name |
N/A |
|
Available Temperature Settings (with remote) |
90 to 140°F (increment of 1°F) |
|
Default Temperature Setting (without remote) |
N/A |
|
Default Temperature Program Setting Options (without remote) |
N/A |
|
Production Date Range |
01/16 |
|
Technical Specs & Installation
Min Gas Input (Btu) |
18000 |
|
Max Gas Input (Btu) |
199900 |
|
Height (in) |
27 |
|
Width (in) |
18.5 |
|
Depth (in) |
12.8 |
|
Weight (lbs) |
95 |
|
Thermal Efficiency |
|
|
Energy Factor |
N/A |
|
Afue |
95.0% |
|
Quick-Connect Compatible? |
No |
|
Cold Water Connection Size (in) |
3/4 |
|
Hot Water Connection Size (in) |
3/4 |
|
Gas Connection Size (in) |
3/4 |
|
Power Supply |
120 VAC (60 Hz) |
|
Current Draw (A) |
1.75 |
|
Exhaust Vent Diameter Requirements |
2" or 3" |
|
Exhaust Vent Material Requirements |
PVC or CPVC or Polypropylene* |
|
Max Vent Length with 1 elbow |
96’ with 3" or 51’ with 2" |
|
Vent Termination Clearances to Any Building Opening (ft) |
Below = 1’, Side = 1’, or Above = 1’ |
|
Gas Supply Pressure Range |
3.5-10.5" WC |
|
Min Gas Line Size |
3/4" up to 30’ |
|
Water Pressure Rating (psi) |
15-150 |
|
Case Clearances (in) |
Top = 12", Front = 4", Sides = 2", Back = 5/8", Below = 12" |
|
Combustion Air Requirements - using Indoor Air |
199 in² (Only if SV conversion) |
|
Combustion Air Requirements - using Outdoor Air |
100 in²(Only if SV conversion) |
|
Head Loss at 2 gpm |
|
|
Cold Connection Height |
|
|
Power Consumption w/out Freeze Prevention |
210 Watts |
|
Power Consumption w/Freeze Prevention |
210 Watts |
|
Flow Meter Alarm |
N/A |
|
Service Reminder |
No |
|
Condensate Handling Method? |
NC-1 |
|
Noise Rating (dB) |
Less than 60 dB |
|
Tested to UL Computer Controlled Safety Standards |
Yes |
|
Flame Sensor |
Yes |
|
High Limit Switch |
Yes |
|
Lightning Protection |
Yes |
|
Overheat Cutoff Fuse) |
Yes |
|
Temperature Lockout |
Yes |
|
Ignition Type |
Direct Electronic |
|
Case Material |
Durable Steel Casing with Polyester Coating |
|
Color/Finish |
Black |
|
Flue Collar Material |
PP |
|
Primary Heat Exchanger Material |
Stainless Steel |
|
Secondary Heat Exchanger Material |
Stainless Steel |
|
Mounting Type |
Wall Hung |
|
Package Contents |
Anchoring Screws, Wall Mounting Bracket, Emergency Kit, Owner’s Guide, Warranty, Installation Manual, Quick Installation Manual, Outdoor Temperature Sensor |
|
Water Holding Capacity |
Under 2 gallons |
|
Accessories
Keypad/Thermostat Display |
Built-in |
|
Compatible Remote Controller Part # |
|
|
Isolator Valve Part # |
IK-WV-200-1-xx |
|
Freeze Protection |
Yes |
|
Freeze Protection Kit Accessory |
|
|
Outdoor Vent Cap Part # |
N/A |
|
Pipe Cover Part # |
PC-1S |
|
Recess Box Part # |
N/A |
|
High Elevation Adjustment |
No |
|
Quick-Connect Cord Part # |
N/A |
|
System Controller Compatible? |
No |
|
System Controller Part # |
N/A |
|
Remote Controller Cord |
N/A |
|
Compatible Remote Controller Cord Part # |
N/A |
|
Power Cord |
Included attached |
|
Approvals
ENERGY STAR® Qualified |
Yes |
|
CSA |
Yes |
|
Mobile Home |
No |
|
NSF |
No |
|
SCAQMD (20 ppm) |
Yes |
|
SCAQMD (55 ppm) |
No |
|
UPC |
No |
|
Energy Guide - Est. Yearly Energy Use |
|
|
Energy Guide - Est. Yearly Operating Cost |
|
|
UPC Low Lead |
NSF372 |
|
ASME (HLW) |
No |
|
ASME (H) |
Yes |
|
ASME (NB) |
No |
|
Warranty
Heat Exchanger Warranty (w/out Recirculation) |
10 Years |
|
Heat Exchanger Warranty (w/Recirculation) |
3 Years |
|
Parts Warranty |
5 Years |
|
Labor Warranty |
1 Year |
|